Byond BYS-820 Single Channel Infusion Pump

39,500.00৳ 

+ Free Shipping

Specifications:

Product Name: Infusion Pump
Brand Name: BYOND
Model Number: BYS-820
Place of Origin: Hunan, China
Power Source: Electric
Warranty: 1 Year
Material: Metal, Plastic
Quality Certification: ce
Instrument classification: Class II
Color: white & grey
Maximum infusion pressure: 150kPa
Volume Limit: 1ml-9999ml
Total Infusion Volume: 0—9999.9ml
Power Consumption: 35VA
Net Weight: 1.8kg
SKU: SLM2488 Category:

Byond BYS-820 Single Channel Infusion Pump

The Byond Infusion Pump BYS–820 is a bubble detector and pressure sensor that detects air bubbles with pinpoint accuracy. To make the injection process safer and more reliable, it has KVO and Bolus functions, a distinctive voice alarm system, and an exact injection rate.

Features:

  • HD LCD Display, high capacity words, friendly user interface, dynamically display working status;
  • Audible and visual alarm for occlusion, empty, low battery, end of infusion, door open, wrong setting, etc., which gain patents;
  • Compatible with any brands of infusion sets after correct calibration;
  • Preset solution volume to greatly reduce the workload of nurses;
  • Work mode: ml/h and drop/min can switch freely;
  • Three levels of occlusion: high, middle and low;
  • Purge function;
  • KVO (keep-vein-open) automatically opens as infusion is completed, KVO rate is 1-5ml/h(1ml/h step);
  • Power Source: AC100—240V, 50/60Hz; Internal Battery;
  • Automatically record the settings of last infusion;
Infusion Rate ml/h mode:1~1200ml/h(1ml/h step)

drop/min mode:1~266drop/min(1drop/min step)

Purge Rate 100mh/h—1200ml/h(can be calibrated)
Flow Rate Accuracy ml/h mode:Within±5%(after correct calibration)

drop/min mode:Within±3%(after correct calibration)

Mechanical Precision Within±2%
Maximum infusion pressure 150kPa
Alarm Pressure High 800mmHg±200mmHg(106.7kPa±26.7kPa)

Medium 500mmHg±100mmHg(66.7kPa±13.3kPa)

Low 300mmHg±100mmHg(40.7kPa±13.3kPa)

Audible and Visible Alarms There are bubbles、Tube is blocked、Close the door、IV set Mismatched、Battery running out、Infusion finish、Equipment
failure、Abnormally Operation、Software Exception、Low battery、 forget the operations etc
Transport&Storage Condition Temperature -20℃~+55℃

Relative Humidity ≤95%

Atmospheric Pressure 50.10KPa—106.0KPa

Infusion Set Compatible with any brand of infusiong sets ater correct calibration The following brands of infusiong sets are
recommended:GEA、Onemed、SHINVA
Infusion maximum value (under single fault condition) 1ml
Forbidden Not support blood Infusion
Dimension 140mm(L)×157mm(W)×220mm(H)
Net Weight 1.8kg
Package Reference 1pcs  Carton:2.8KG,33cm(L)×28cm(W)×26cm(H)

2pcs Carton:6.5KG,52cm(L)×30cm(W)×36cm(H)

3pcs Carton:9.6KG,76cm(L)×30cm(W)×36cm(H)

Reviews

There are no reviews yet.

Be the first to review “Byond BYS-820 Single Channel Infusion Pump”

Your email address will not be published. Required fields are marked *

Shopping Cart